Balzers Tpg 300 Manual

Posted by admin

Here we offer you a Pfeiffer HPA 220 mass spectrometer.HPA 220, for process pressure up to 8 hPa, HPI 040 H, manually operatedHPA 220, High Pressure Analyzer, Mass Range 1 - 200 amu, 115 - 230 V, 50/60 Hz,for process and residual gas analysis in the pressure range 8 hPa p. 1. 10-7 hPaconsisting of:PrismaPlus with quadrupole electronics QME 220Valve interface HPI 040 HControl Panel BRU 220 with power supply TPS 311 and remote connection for external accessTurbo molecular pumping station. Here we offer you a Pfeiffer HiCube 300 Classic Vacuum turbo pump.Pfeiffer HiCube 300 Classic Vacuum Turbo PumpCombined pumping station with turbo pump and pre-pump for all applications in high vacuumConnection flange (output) G 1/2, G 1/4Connection flange (input) DN 100 ISO-KFinal pressure s. 10-7 hPa. 7.5. 10-8 Torr.

1 10-7 mbarFinal pressure without gas ballast. 10-7 hPa. 7.5.

Balzers Tpg 300 Manual

Balzers Tpg 300 Manual Pdf

10-8 Torr. 1 10-7 mbarWei. Here we offer you a Pfeiffer HiCube 300 Classic Vacuum turbo pump.Pfeiffer HiCube 300 Classic Vacuum Turbo PumpCombined pumping station with turbo pump and pre-pump for all applications in high vacuumConnection flange (output) G 1/2, G 1/4Connection flange (input) DN 100 ISO-KFinal pressure s. 10-7 hPa. 7.5.

10-8 Torr. 1 10-7 mbarFinal pressure without gas ballast. 10-7 hPa. 7.5. 10-8 Torr. 1 10-7 mbarWei.

Manual

Balzers Tpg 300 Manual 2017

The Pfeiffer Vacuum / Balzers Cold Cathode Measurement Boards for TPG 300 Total Pressure Gauge Controller Cold for the measurement of high and ultra high vacuum contain one or two measurement circuits, each with one gauge cable connector and one analog signal output. When the gauge is turned on, the analog signals are constantly available, independent of what is shown on the pressure display. These measurement boards contains special electronics to limit the measurement current to 100 µA, a feature that considerably extends the lifetime of the gauge.The current flowing in a self-sustained gas discharge with a cold cathode (similar to Penning) depends on the applied voltage, the gas composition, and the pressure.

A magnetic field that penetrates the measurement chamber has the effect that the electrons move along a spiral trajectory from the cathode to the anode and thereby cause even at low gas densities a sufficient number of ionizing impacts for maintaining the discharge. If (with a known gas type) the anode voltage and magnetic field are kept constant, the discharge current is a measure of the pressure. Buying used equipment doesn't always have to be a shot in the dark. We know there are plenty of differences when it comes to used equipment and quite often, choosing between different pieces is difficult, especially when the equipment is not sitting right in front of you.Well, what if you were able to see a piece of equipment before you purchased it? Not just a picture from the manufacturer's website, but the actual piece of equipment you would receive.With InstraView™, we move you one step closer to inspecting the equipment you're interested in without having to wait for the equipment to show up at your door.InstraView™ works in your web browser and allows you to view the actual piece of equipment you're interested in before purchasing. You can zoom in close to see the labels with the serial number or zoom out to see the overall condition of the equipment.It's like having the store come to you!